  1 power entry modules with line filter ef12 https://www.schurter.com /pg06 emc products iec appliance inlet c20 with filter, circuit breaker ta45 (recessed) approvals and compliances c20 70 c description - panel mount : screw-on mounting from front side - 3 functions : appliance inlet protection class i , circuit breaker type ta45 2-pole , line filter in standard and medical version - quick connect terminals 6.3 x 0.8 mm characteristics - all single elements are already wired - circuit breaker non-illuminated or illuminated - with emc-shield - suitable for use in equipment according to iec/ul 60950 suitable for use in medical equipment according to iec/ul 60601-1 other versions on request - variant with notch for v-lock mating cordsets references alternative: version without line filter ef11 alternative: standard version weblinks pdf datasheet, html-datasheet, general product information, distributor- stock-check, accessories, detailed request for product, microsite technical data ratings iec 12 - 16 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 12 - 20 a @ ta 40 c / 250 vac; 60 hz leakage current standard < 0.5 ma (250 v / 60 hz) medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation tempe - rature -10 c to 55 c climatic category 10/055/21 acc. to iec 60068-1 ip-protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class i acc. to iec 61140 terminal quick connect terminals 6.3 x 0.8 mm panel thickness s screw: max 8 mm mounting screw torque max 0.5 nm material: housing thermoplastic, black, ul 94v-0 appliance inlet/-outlet c20 acc. to iec 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 16 a, protection class i circuit breakers acc. iec/en 60934, ul 1077, csa 22.2 no. 235 2-pole rocker switch, illuminated or non- illuminated. optional with undervoltage- or remote trip release short circuit capacity icn: at in < 3a/240vac : 10 x in at in 3a/240vac : 300a line filter standard and medical version, iec 60939, ul 1283, csa c22.2 no. 8 technical details mtbf > 100'000 h acc. to mil-hb-217 f approvals and compliances detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in details about approvals approvals the approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. approval reference type: ef12 approval logo certificates certification body description vde approvals vde certificate number: 40001520 ul approvals ul ul file number: e72928
2 power entry modules with line filter ef12 https://www.schurter.com /pg06 emc products product standards product standards that are referenced organization design standard description designed according to iec 60320-1 appliance couplers for household and similar general purposes designed according to iec 60939 passive filters for suppressing electromagnetic interference designed according to iec 61058-1 switches for appliances. part 1. general requirements designed according to ul 498 standard for attachment plugs and receptacles designed according to ul 1283 electromagnetic interference filters designed according to csa c22.2 no. 42 general use receptacles, attachment plugs, and similar wiring devices designed according to csa c22.2 no. 8 electromagnetic interference (emi) filters application standards application standards where the product can be used organization design standard description designed for applications acc. iec/ul 60950 iec 60950-1 includes the basic requirements for the safety of information technologyequipment. designed for applications acc. iec 60601-1 medical electrical equipment - part 1: general requirements for basic safety and essential performance compliances the product complies with following guide lines identification details initiator description ce declaration of conformity schurter ag the ce marking declares that the product complies with the applicable requirements laid down in the harmonisation of community legislation on its affixing in accordance with eu regulation 765/2008. rohs schurter ag eu directive rohs 2011/65/eu china rohs schurter ag the law sj / t 11363-2006 (china rohs) has been in force since 1 march 2007. it is similar to the eu directive rohs. reach schurter ag on 1 june 2007, regulation (ec) no 1907/2006 on the registration, evaluation, authorization and restriction of chemicals 1 (abbreviated as "reach") entered into force. micrositev-lock schurter ag v-lock system are based on a matching plug-dose combination. the connector is equipped with a notch intended for use with the latching cordset. the cord latching system prevents against accidental removal of the cordset. medical equipment schurter ag suitable for use in medical equipment according to iec/ul 60601-1
3 power entry modules with line filter ef12 https://www.schurter.com /pg06 emc products dimension [mm] ?3.3 90 101 ?6.4 33.9 59.5 5.3 12.2 40.55 79.2 10.9 32.2 37 41.2 10.6 76.2 2.8 5.5 r 6.5 r 4.7 r 2.8 0.8 12.6 80.05 32.9 r 3.05 0.10 90 0.10 ?3.6/m3 0.05 r 3.55 0.10 81 0.05 4.55 9.5 * --- version ta45 with undervoltage release technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m? ] 12 standard version 2 x 0.8 100 2.2 1 16 standard version 2 x 0.6 100 2.2 1 20 standard version 2 x 0.3 100 2.2 1 12 medical version (m5) 2 x 0.8 100 - 1 16 medical version (m5) 2 x 0.6 100 - 1 20 medical version (m5) 2 x 0.3 100 - 1 diagrams standard version cx l1 l2 cy cy 2) l? pe? n? p1 p2 l pe n 1) ta 45 r 1) line 2) load medical version (m5) cx l1 l2 r 2) l? pe? n? p1 p2 l pe n 1) ta 45 1) line 2) load
4 power entry modules with line filter ef12 https://www.schurter.com /pg06 emc products attenuation loss - - - - 50? differential mode _____ 50? common mode standard version 12 a 16 a 20 a medical version (m5) 12 a 16 a 20 a
5 power entry modules with line filter ef12 https://www.schurter.com /pg06 emc products ab t w f 150 c0 colours switch fr ont rocker w black white ? b black black ? 6 black ? orange transp. f embossed h printed white k printed black l printed white surface illustration colour of print rocker legend l o on off on off l o m printed black p printed white r printed black surface illustration colour of print i n code 10,0 100 11,0 110 12,0 120 i n code 13,0 130 14,0 140 15,0 150 i n code 16,0 160 17,0 170 18,0 180 i n code 19,0 190 20,0 200 without r elease: code c0 undervoltage r elease remote trip r elease ue za code rated voltage u n ? ? ? ? ? ? ? ? ? ? ? ? 2 3 4 240 v ac 230 v ac 120 v ac l o o i o i position of the r ocker legend e.g f rated curr ent cir cuit br eaker of equipment t able 1 selection for type t a45 or der example ? cir cuit br eaker of equipment ? 2-pole, r ocker actuated ? quick connect terminal other variants on r equest w ithout illumination w ith illumination 220?240 v 110?120 v 3 5 p 1 a diagram thermal overload pr otection 1-pole 2-pole abt abd a12 a32 a14 a34 } other rated curr ents on r equest p2 p1 u< p2 p1 c p2 p1 6 3 43 p2 p1 p2 p1 b u< p2 p1 b a u<
6 power entry modules with line filter ef12 https://www.schurter.com /pg06 emc products * ambient temperatur e [c] corr ection factor ?10 0,89 ?5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 t echnical data (continued) cir cuit br eaker t ripping characteristics i n < 3 a t ripping characteristics i n > 3? < 18 a t ripping characteristics i n > 18 a t ype ta 45 rated curr ent i n <3 a 1 pole pr otected 2 pole pr otected ambient temp. +23 c 10'000 60 2`000 1`000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 multiple of rated curr ent [ x i n ] 10 8 5 4 3 2 1,32 tr ipping time t ype ta 45 rated curr ent i n > 3 a... < 18 a 1 pole pr otected 2 pole pr otected ambient temp. +23 c 10'000 60 2`000 1`000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 multiple of rated curr ent [ x i n ] 10 8 5 4 3 2 1,32 tr ipping time t ype ta 45 rated curr ent i n 18 a 1 pole pr otected 2 pole pr otecte d ambient temp. +23 c tr ipping time 10'000 60 2`000 1`000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 multiple of rated curr ent [ x i n ] 10 8 5 4 3 2 1,32 > 1) ef fect of ambient temperatur e the unit is calibrated for an ambient tem pe ratur e of +23 c. to de- termine the rated curr ent for a lower or higher ambient temperatur e, use a corr ection factor fr om the table on the right side: 1) example rated curr ent at +23 c 6,0 a ambient temperatur e +40 c corr ection factor 1,08 chosen rated curr ent at +40 c ambient temperatur e 6 a x 1,08 = 6,5 a * t emperatur e must be measur ed at the r ear of the br eaker next to the terminals after equipment operating temperatur e has been reached. configuration code (example) color 0 black interlocking 0 without v -lock 1 with v -lock t erminal pe 1 qc 6.3x0.8 t erminal l and n 1 qc 6.3x0.8, without connection to t a45 3 connection to t a45 non insulated t ype of mains ? lter / capacitor / bleed r esistor 1 standar d x2,y2 with bleed r esistor 2 medical m5 x2 with bleed r esistor rated curr ent 1) 1 20 a 2 16 a 3 12 a 1) the rated curr ent of the line-? lter must be equal or mor e than the rated curr ent of t a45. ef12 - ABTWF150C0 - 000 - 1111 - 00 - 00 t ype or der code t a45 (2-pole r ocker -switch without accessories) see table 1
7 power entry modules with line filter ef12 https://www.schurter.com /pg06 emc products packaging unit 16 pcs accessories description cord retaining kits cord retaining strain relief flat head, h 4700.0008 mating outlets/connectors category / description connector overview complete iec connector c19, rewireable, straight 4795 iec connector c19, rewireable, angled 4790 iec connector c19, rewireable, straight 0104u connector further types to ef12 mating outlets/connectors shuttered power cord overview complete overview power cord with iec appliance connector c19, v-lock, straight vac19ks power cord further types to ef12 the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments. information furnished is believed to be accurate and reliable. however, users should independently evaluate the suitability and test each product selected for their own applications. 02.12.2017


▲Up To Search▲   

 
Price & Availability of ABTWF150C0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X